HP 65 amp nozzle vs. 45 amp

Hypertherm Plasma Cutter discussion forum.
Post Reply
abmetal
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 813
Joined: Mon Dec 26, 2011 8:37 pm
Location: Southeast Missouri

HP 65 amp nozzle vs. 45 amp

Post by abmetal »

Jim (or anybody else),

I have a Powermax 65 and presently use 65 amp and 45 amp finecut nozzles. Is there any advantage/disadvantage to using a 45 amp (220941) versus a 65 amp set at 45 amps?

Allen
User avatar
Francisco
2.5 Star Member
2.5 Star Member
Posts: 178
Joined: Tue Feb 23, 2010 4:17 pm

Re: HP 65 amp nozzle vs. 45 amp

Post by Francisco »

Thinner kerf, better angularity. Compared to the Finecut parts, your kerf will be wider, but nozzles will last far longer. I think your cut speed will be higher, too, but you'd better check the tables to confirm (I don't have them here).

Best of luck!
abmetal
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 813
Joined: Mon Dec 26, 2011 8:37 pm
Location: Southeast Missouri

Re: HP 65 amp nozzle vs. 45 amp

Post by abmetal »

I realize the kerf would be wider than the finecut, but would the cut be basically the same as the 65 amp turned down to 45 amps. As I'd mentioned earlier, we've never used the 45 amp and I was wondering if there'd be any advantage to them other than running at a lower amperage.

Allen
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: HP 65 amp nozzle vs. 45 amp

Post by jimcolt »

If you use any nozzle at less than its design amperage you will get a lower energy density arc, this will cause slower cuts speeds, worse edge angularity, dross, warpage. If yoy want to cut at 45 amps the best performance is with a 45 amp nozzle.

Jim Colt



abmetal wrote:Jim (or anybody else),

I have a Powermax 65 and presently use 65 amp and 45 amp finecut nozzles. Is there any advantage/disadvantage to using a 45 amp (220941) versus a 65 amp set at 45 amps?

Allen
abmetal
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 813
Joined: Mon Dec 26, 2011 8:37 pm
Location: Southeast Missouri

Re: HP 65 amp nozzle vs. 45 amp

Post by abmetal »

Jim, that's what I needed to know. And just out of curiousity...other than maybe the hole, what's the physical difference between the 45 and 65 amp nozzles?

Thanks,
Allen
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: HP 65 amp nozzle vs. 45 amp

Post by jimcolt »

They are very similar. They are also patented for their "conical Flow" technology. The 85 amp and 105 amp nozzles for the larger systems (Powermax85 and Powermax105) are similar as well, same torch.

Jim
abmetal wrote:Jim, that's what I needed to know. And just out of curiousity...other than maybe the hole, what's the physical difference between the 45 and 65 amp nozzles?

Thanks,
Allen
Post Reply

Return to “Hypertherm Plasma Cutters”