ProLine 2200 Issues

Post by klkdiver5409 »

New here from Hanover Pa.
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

Welcome! Plenty of help here I have found, what sort of issues are you having?
DIY 4x8 table
Powermax 65
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

We are having a fuse that keeps blowing and have traced most all wires coming out of the fuse. It’s only a 5a fuse but somewhere has to been shorted out
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

The fuse is marked as F4. I appreciate your quick response
hardworker
1.5 Star Elite Contributing Member
1.5 Star Elite Contributing Member
Posts: 61
Joined: Thu Aug 06, 2020 3:17 pm
Location: Wisconsin/ Minnesota

Re: ProLine 2200 Issues

Post by hardworker »

I'm not familiar with your set up. Is it possible it just needs a higher amp fuse? I've seen it before where someone uses whatever they have an put a smaller amp fuse then originally called for. just a idea... Good luck
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

I do you have the schematic with the machine and it caused for a five amp fuse. I am thinking we have a dead short somewhere.
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

klkdiver5409 wrote: Wed Apr 10, 2024 4:35 pm We are having a fuse that keeps blowing and have traced most all wires coming out of the fuse. It’s only a 5a fuse but somewhere has to been shorted out
You mention "traced most all wires coming out of the fuse". If there are numerous wires coming out of the fuse I would be inclined to disconnect them all, install a new fuse, and then reconnect them all 1 by 1 until the fuse blows to find the culprit circuit or component.
DIY 4x8 table
Powermax 65
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

I like that idea, Thank you!
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

No problem, I sure hope it helps you out. Let us know what you find.
DIY 4x8 table
Powermax 65
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

I wish there was a way to download pictures. There is a remote wire 9 pin amphenal plug and the center wire is going to ground, yet on the 9 pin receptacle on the machine is 24v coming from power switch. Obviously 24v wire cannot go to ground. Very confusing but not hooking that ground wire and not blowing the fuse the machine is powering on
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

You can upload pictures if that is what you mean but not in the quick reply window, you need to click on "Full Editor and Preview" below the quick reply window and you will see whats shown below and you can add files pics etc.
pics.PNG
DIY 4x8 table
Powermax 65
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

klkdiver5409 wrote: Fri Apr 12, 2024 9:01 am I wish there was a way to download pictures. There is a remote wire 9 pin amphenal plug and the center wire is going to ground, yet on the 9 pin receptacle on the machine is 24v coming from power switch. Obviously 24v wire cannot go to ground. Very confusing but not hooking that ground wire and not blowing the fuse the machine is powering on
And the machine functioned before with that hooked up?
DIY 4x8 table
Powermax 65
klkdiver5409
1/2 Star Member
1/2 Star Member
Posts: 7
Joined: Wed Apr 10, 2024 2:19 pm

Re: ProLine 2200 Issues

Post by klkdiver5409 »

Yes Sir
kicktillmonday
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 185
Joined: Tue Aug 30, 2022 9:34 am

Re: ProLine 2200 Issues

Post by kicktillmonday »

Well that is odd. I would look to see where that 24v is coming from and what it's for. Hopefully you can get a wiring schematic of your machine to shed some light on that circuit and whats going on. In the meantime are you able to cut with no issues?
DIY 4x8 table
Powermax 65