ProLine 2200 Issues
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
ProLine 2200 Issues
New here from Hanover Pa.
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
Welcome! Plenty of help here I have found, what sort of issues are you having?
DIY 4x8 table
Powermax 65
Powermax 65
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
We are having a fuse that keeps blowing and have traced most all wires coming out of the fuse. It’s only a 5a fuse but somewhere has to been shorted out
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
The fuse is marked as F4. I appreciate your quick response
-
- 1.5 Star Elite Contributing Member
- Posts: 61
- Joined: Thu Aug 06, 2020 3:17 pm
- Location: Wisconsin/ Minnesota
Re: ProLine 2200 Issues
I'm not familiar with your set up. Is it possible it just needs a higher amp fuse? I've seen it before where someone uses whatever they have an put a smaller amp fuse then originally called for. just a idea... Good luck
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
I do you have the schematic with the machine and it caused for a five amp fuse. I am thinking we have a dead short somewhere.
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
You mention "traced most all wires coming out of the fuse". If there are numerous wires coming out of the fuse I would be inclined to disconnect them all, install a new fuse, and then reconnect them all 1 by 1 until the fuse blows to find the culprit circuit or component.klkdiver5409 wrote: ↑Wed Apr 10, 2024 4:35 pm We are having a fuse that keeps blowing and have traced most all wires coming out of the fuse. It’s only a 5a fuse but somewhere has to been shorted out
DIY 4x8 table
Powermax 65
Powermax 65
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
I like that idea, Thank you!
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
No problem, I sure hope it helps you out. Let us know what you find.
DIY 4x8 table
Powermax 65
Powermax 65
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
I wish there was a way to download pictures. There is a remote wire 9 pin amphenal plug and the center wire is going to ground, yet on the 9 pin receptacle on the machine is 24v coming from power switch. Obviously 24v wire cannot go to ground. Very confusing but not hooking that ground wire and not blowing the fuse the machine is powering on
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
You can upload pictures if that is what you mean but not in the quick reply window, you need to click on "Full Editor and Preview" below the quick reply window and you will see whats shown below and you can add files pics etc.
DIY 4x8 table
Powermax 65
Powermax 65
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
And the machine functioned before with that hooked up?klkdiver5409 wrote: ↑Fri Apr 12, 2024 9:01 am I wish there was a way to download pictures. There is a remote wire 9 pin amphenal plug and the center wire is going to ground, yet on the 9 pin receptacle on the machine is 24v coming from power switch. Obviously 24v wire cannot go to ground. Very confusing but not hooking that ground wire and not blowing the fuse the machine is powering on
DIY 4x8 table
Powermax 65
Powermax 65
-
- 1/2 Star Member
- Posts: 7
- Joined: Wed Apr 10, 2024 2:19 pm
Re: ProLine 2200 Issues
Yes Sir
-
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Tue Aug 30, 2022 9:34 am
Re: ProLine 2200 Issues
Well that is odd. I would look to see where that 24v is coming from and what it's for. Hopefully you can get a wiring schematic of your machine to shed some light on that circuit and whats going on. In the meantime are you able to cut with no issues?
DIY 4x8 table
Powermax 65
Powermax 65