Hypertherm powermax 65 will not fire 0-30 trouble code
-
- 1/2 Star Member
- Posts: 4
- Joined: Sat Oct 20, 2012 10:27 am
Hypertherm powermax 65 will not fire 0-30 trouble code
The plasma cutter was doing fine until i noticed it was not square to the plasmacam table so i readjusted an now the torch will not fire any help would be great
-
- 5 Star Elite Contributing Member
- Posts: 3087
- Joined: Mon Jul 20, 2009 11:18 pm
- Location: North Carolina
Re: Hypertherm powermax 65 will not fire 0-30 trouble code
If it is a hand torch you can get this error with the clamps overtightened. This distorts the internal components of the torch and does not allow the electrode to move freely in the torch.
Jim Colt Hypertherm