cut/pierce 1"

Hypertherm Plasma Cutter discussion forum.
Post Reply
Catgraphics
1 Star Member
1 Star Member
Posts: 24
Joined: Mon Mar 21, 2011 11:35 am

cut/pierce 1"

Post by Catgraphics »

Hello I hope you all can help or give me an idea I am running a powermax 1250 cutting 1?. #1 Can I pierce it at 80 a or should I drill the pierce point? #2 how much peirce/cut should I get out of a tip and shield?
Thanks
User avatar
JJsCustomDesigns
3.5 Star Member
3.5 Star Member
Posts: 570
Joined: Thu Jul 07, 2011 12:29 pm
Location: Nebraska

Re: cut/pierce 1"

Post by JJsCustomDesigns »

I also run a PM1250. I wanna say the 1250 can only pierce upto 5/8 and do an edge start on 3/4. But ive done 1" from an edge start @ around 11ipm and 80amps. I got a pretty good cut. But still had bevel.
"There are bigger things planned for you in your life, be patient"

Im on the prowl for a good used Hypertherm Plasma with hand torch.
PM me with details
Thanks
natewelding
2 Star Member
2 Star Member
Posts: 72
Joined: Mon Mar 18, 2013 2:30 pm
Location: Buffalo NY

Re: cut/pierce 1"

Post by natewelding »

definitely cannot piece with 80. edge start or drill a hole first, if you cant make a leadin at the edge
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: cut/pierce 1"

Post by jimcolt »

The 1250 is advertised to pierce 5/8"....so to do 1" you should edge start....the edge of a drilled hole works the same as an edge start. If you upgrade the 1250 to the newer ytechnology Duramax torch...then you can pierce 3/4" without issue.

If you pierce 5/8" at the recommended pierce height and pierce delay time (from the mechanized cut charts in the operators manual) you will get at least 300 pierces without damage to the shield or nozzle (there is not a "tip")

Jim Colt

Catgraphics wrote:Hello I hope you all can help or give me an idea I am running a powermax 1250 cutting 1?. #1 Can I pierce it at 80 a or should I drill the pierce point? #2 how much peirce/cut should I get out of a tip and shield?
Thanks
Post Reply