HPR 260 limit switch lights off torch

Hypertherm Plasma Cutter discussion forum.
Post Reply
retiredcpo
2 Star Member
2 Star Member
Posts: 95
Joined: Thu Nov 17, 2011 9:21 pm

HPR 260 limit switch lights off torch

Post by retiredcpo »

Just a FYI we are using a HP260XD on a retro system table
when we are done cutting a parts and the sceen says "do you want to return the the start yes or no"
If you bump any of the limit switches the torch will fire.
Retiredcpo
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: HPR 260 limit switch lights off torch

Post by jimcolt »

You will need to contact tech support at Retro Systems and get this issue resolved. If you contact me directly and supply your contact information (name, company name and location/contact info) I will forward your info directly to Retro Systems.

Best regards, Jim Colt jim.colt@hypertherm.com

retiredcpo wrote:Just a FYI we are using a HP260XD on a retro system table
when we are done cutting a parts and the sceen says "do you want to return the the start yes or no"
If you bump any of the limit switches the torch will fire.
Retiredcpo
retiredcpo
2 Star Member
2 Star Member
Posts: 95
Joined: Thu Nov 17, 2011 9:21 pm

Re: HPR 260 limit switch lights off torch

Post by retiredcpo »

Jim
We contacted retro system the day we found the issue it happens on thier table as well
they are working on a fix now
just thought I would let others know it could light off when not expected