30 amp settings for a Thermal Dynamics cutmaster A80

Cut quality issues can be discussed here, most common issues have been discussed here and should help you.
Post Reply
scooper
1/2 Star Member
1/2 Star Member
Posts: 4
Joined: Sat Sep 28, 2013 10:34 pm

30 amp settings for a Thermal Dynamics cutmaster A80

Post by scooper »

I am looking for 30 anp tools does anyone have any or know where i can find them? Thanks!
User avatar
mlinehan
1.5 Star Member
1.5 Star Member
Posts: 29
Joined: Tue Apr 23, 2013 8:48 am

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by mlinehan »

30 amp cut speed chart:

30A, 1/16" standoff

18ga 240 ipm
12ga 120 ipm
6 ga 40 ipm
1/4" 20 ipm
3/8" 10 ipm
scooper
1/2 Star Member
1/2 Star Member
Posts: 4
Joined: Sat Sep 28, 2013 10:34 pm

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by scooper »

Thanks for the reply how can i also get the Kerf with, Pierce delay, Pierce hight, Plunge rate, Cut hight, Voltage & what the best air pressure to run per material and thickness. Thanks
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by jimcolt »

Isn't that information all listed in the cut charts in your Cutmaster operators manual?

Jim Colt

scooper wrote:Thanks for the reply how can i also get the Kerf with, Pierce delay, Pierce hight, Plunge rate, Cut hight, Voltage & what the best air pressure to run per material and thickness. Thanks
scooper
1/2 Star Member
1/2 Star Member
Posts: 4
Joined: Sat Sep 28, 2013 10:34 pm

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by scooper »

The cut charts only go to 40Amp
billy55
1.5 Star Member
1.5 Star Member
Posts: 34
Joined: Wed May 02, 2012 7:20 am
Location: Merkel, Texas

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by billy55 »

This is what i use for 30 amp on my A-80 and works fine for 16 and 14 ga .029 kerf width,90 ipm [water table], pierce delay .2,pierce height.06,cut height .05. 95 vlts.
Plasmaroute HD 4x4 TD A-80
scooper
1/2 Star Member
1/2 Star Member
Posts: 4
Joined: Sat Sep 28, 2013 10:34 pm

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by scooper »

Thanks for the help
Little Leonard
1.5 Star Member
1.5 Star Member
Posts: 37
Joined: Sun Jul 14, 2013 1:08 pm

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by Little Leonard »

I run a 82 on my table and the manual is no where near the speeds I cut at or hight
4x8 Precison plasma table
Candcnc
Sheetcam,Mach3
TD cutmaster 82
plumbrob
1/2 Star Member
1/2 Star Member
Posts: 1
Joined: Sun Jan 26, 2014 10:35 am
Location: Kingston Ontario

Re: 30 amp settings for a Thermal Dynamics cutmaster A80

Post by plumbrob »

I have TD cutmaster 82 and I find the speeds are really close to the book, but my only goes down to 40amps the book that is
Post Reply