HT 380 Q?

Hypertherm Plasma Cutter discussion forum.
Post Reply
MIFab
3 Star Member
3 Star Member
Posts: 251
Joined: Tue Apr 16, 2013 8:47 pm

HT 380 Q?

Post by MIFab »

Ok so I m just getting started with my set up and I'm trying to get my setting correct on my DHC Plasmacam v3.11 with the HT 380. I incurred a problem with the torch cap led blinking in the manual it reads Pilot arc "misfires" or circuit not complete . I took it off the table and tried using it and it would stop working I would tap the gun and would work for a few cuts then trip so on and so on... when on the table I can cut every other letter but if I use the pause before cut it will cut it all.
planetxfred
2 Star Member
2 Star Member
Posts: 53
Joined: Thu Mar 11, 2010 5:45 pm

Re: HT 380 Q?

Post by planetxfred »

Sounds like a poor connection or something binding. If the parts are tightened too much or dirt inside, it can bind & make for poor starts. Take the consumables apart, blow everything clean, lube appropriate parts with the correct lube, put back together _Gently_.
Fred
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: HT 380 Q?

Post by jimcolt »

An overtightened retaining cap is the common culprit when this error occurs. Although a worn out retaining cap or swirl ring can cause it as well. The electrod has to slide freely inside the torch....overtightening the cap can cause the swirl ring to distort and will limit the electrode movement.


Jim
MIFab wrote:Ok so I m just getting started with my set up and I'm trying to get my setting correct on my DHC Plasmacam v3.11 with the HT 380. I incurred a problem with the torch cap led blinking in the manual it reads Pilot arc "misfires" or circuit not complete . I took it off the table and tried using it and it would stop working I would tap the gun and would work for a few cuts then trip so on and so on... when on the table I can cut every other letter but if I use the pause before cut it will cut it all.
MIFab
3 Star Member
3 Star Member
Posts: 251
Joined: Tue Apr 16, 2013 8:47 pm

Re: HT 380 Q?

Post by MIFab »

I always hate it I come across a post and it hasn't been completed. The issue I ended up having was the micro switch in the gun its self was bad I replaced that and it works great .
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: HT 380 Q?

Post by jimcolt »

Thanks for the update!

Jim
Post Reply