So I'm new to the cnc plasma world I picked up a PlasmaCam 98z that had never been hooked up two weeks ago and have it cutting...and filling my 28x30 shop up with smoke in a matter of seconds. I have had a gable vent fan in the wall since I built and with a door cracked it will clear out the smoke in a few minutes but still covers everything in dust. So I built a water pan rolls under the table's original grate so water is 4"-5" below the metal grate. It was only a marginal success cut down on some but the smoke was still overwhelming so I'm on to a downdraft set up. My plan was to enclose the base of the table and run ducting out the back wall of the shop (into a hill and no neighbors). This would still allow me to run the water table if wanted but would I be better off to build the hopper style for increased suction?? I've sourced this used vent fan (I'm not really wanting to spend $500 on a fan right now) The cfm isn't listed on the fan and the web site has that model listed with different sizes and from 42cfm - 32,000cfm! My plan was to have a short duct run and use make up air from the door (goodbye heat) for now with thoughts of a make up vent near the table in the future. Thoughts & input?? Thanks Travis
You currently do not have access to download this file.
To gain download access for DXF, SVG & other files Click Here
- jmsrbrt
- 3 Star Member
- Posts: 382
- Joined: Mon Dec 08, 2008 5:24 pm
- Location: San Marcos, TX
- Contact:
Re: Fan for down draft, opinions please
My 2 cents...get your water closer to the metal. 4-5 inches is a LONG way. I have my water close, and no more than 1-2 inches...pert near no smoke.
Bob
Bob
Torchmate 2 with ATHC & Water table
Corel 12, Turbo Cad
TD Cutmaster 51
San Marcos, Texas
Corel 12, Turbo Cad
TD Cutmaster 51
San Marcos, Texas
-
- 3.5 Star Member
- Posts: 537
- Joined: Sun Feb 10, 2013 3:13 pm
- Location: mich.
Re: Fan for down draft, opinions please
you need the water 1/2 inch to a inch below the plate
or you need to build a plenum or what ever its called for the vent fan to work properly
or you need to build a plenum or what ever its called for the vent fan to work properly
Arclight 4x4
hypertherm 65
corel x6
mach 3, sheet cam
miller 211 auto set
hypertherm 65
corel x6
mach 3, sheet cam
miller 211 auto set
- _Ogre
- 3.5 Star Member
- Posts: 529
- Joined: Sun Sep 15, 2013 4:26 pm
- Location: Motown
Re: Fan for down draft, opinions please
without knowing the cfm of the fan it would be hard for anyone to voice an opinion.
if you heat your shop in a cold weather area of the country i would definitely move the water table up and try that first.
if you heat your shop in a cold weather area of the country i would definitely move the water table up and try that first.
bulltear 4x8 cnc plasma table, candcnc bladerunner w/dthc, hypertherm powermax 65, sheetcam, mach3
laser cross hair for hypertherm torch http://www.plasmaspider.com/viewtopic.php?f=6&t=12508
an ogre smiley how cool!
laser cross hair for hypertherm torch http://www.plasmaspider.com/viewtopic.php?f=6&t=12508
an ogre smiley how cool!
- tnbndr
- 4.5 Star Elite Contributing Member
- Posts: 1688
- Joined: Mon Jan 09, 2012 4:30 pm
- Location: New Berlin, WI
- Contact:
Re: Fan for down draft, opinions please
Coming from an HVAC background and installing tons of those fans that fan looks pretty small (12x12 base?) I would venture to say it won't move more than 400 cfm. and they are made for roof mounting on a curb not sidewall. Mounted on a sidewall the bearing will fail pretty quick.
Dennis
LDR 4x8, Scribe, DTHCIV
Hypertherm PM45, Macair Dryer
DeVilbiss Air America 6.5HP, 80Gal., 175psi, Two Stage
16.9scfm@100psi, 16.0scfm@175psi
Miller 215 MultiMatic
RW 390E Slip Roll (Powered)
AutoCAD, SheetCAM, Mach 3
http://ikescreations.com
LDR 4x8, Scribe, DTHCIV
Hypertherm PM45, Macair Dryer
DeVilbiss Air America 6.5HP, 80Gal., 175psi, Two Stage
16.9scfm@100psi, 16.0scfm@175psi
Miller 215 MultiMatic
RW 390E Slip Roll (Powered)
AutoCAD, SheetCAM, Mach 3
http://ikescreations.com
-
- 2 Star Member
- Posts: 53
- Joined: Thu Mar 11, 2010 5:45 pm
Re: Fan for down draft, opinions please
I would suggest enclosing the sides and making a downdraft system. Use a 1/2 hp belt drive blower from a home furnace, can often pick them up nearly free. Mount so that the fan is near to the wall or even outside (with a shelter),
With decent size duct, you can get near 2000 cfm of flow. That is what I have, I cover open areas of the table with Masonite sheets, You can see the dust being sucked down. The machine stays nice & clean, Same for shop and lungs. I'm in Minnesota and provide a fresh air makeup supply inlet above the table so the incoming COLD air is dropped on top of the table. Fan switches on and off with the torch cutting signal.
Fred
With decent size duct, you can get near 2000 cfm of flow. That is what I have, I cover open areas of the table with Masonite sheets, You can see the dust being sucked down. The machine stays nice & clean, Same for shop and lungs. I'm in Minnesota and provide a fresh air makeup supply inlet above the table so the incoming COLD air is dropped on top of the table. Fan switches on and off with the torch cutting signal.
Fred
-
- 3.5 Star Member
- Posts: 537
- Joined: Sun Feb 10, 2013 3:13 pm
- Location: mich.
Re: Fan for down draft, opinions please
great ideal. its cold here in MI. and am debating on down draft or water heater
is there a special antifreeze for plasma cutters ?
I know you cant use regular antifreeze.
I have the winter off but no heat .
is there a special antifreeze for plasma cutters ?
I know you cant use regular antifreeze.
I have the winter off but no heat .
Arclight 4x4
hypertherm 65
corel x6
mach 3, sheet cam
miller 211 auto set
hypertherm 65
corel x6
mach 3, sheet cam
miller 211 auto set
-
- 2 Star Elite Contributing Member
- Posts: 50
- Joined: Tue Nov 12, 2013 9:42 pm
Re: Fan for down draft, opinions please
That is all good input I appreciate it. The fan base is 18" still not sure on the cfm though. Fred what size ducts are you using. I like the air intake right over the table idea too.