Hypertherm powermax 85 fine cut problems

Discussion on 0-30 fault codes
Post Reply
COLT
1 Star Member
1 Star Member
Posts: 14
Joined: Mon May 20, 2013 2:50 pm

Hypertherm powermax 85 fine cut problems

Post by COLT »

All consumables are brand new and when it tries to start the arc it goes down touches metal air comes on but no arc then fault code 0-30 stuck consumable. Any help please.
COLT
1 Star Member
1 Star Member
Posts: 14
Joined: Mon May 20, 2013 2:50 pm

Re: Hypertherm powermax 85 fine cut problems

Post by COLT »

Every tip I have does not work. I swapped to the hand torch and it fires right up.
COLT
1 Star Member
1 Star Member
Posts: 14
Joined: Mon May 20, 2013 2:50 pm

Re: Hypertherm powermax 85 fine cut problems

Post by COLT »

Walk away ten minutes doing some grinding and the answer pops in your head. Thanks for all the help on the site anyways
COLT
1 Star Member
1 Star Member
Posts: 14
Joined: Mon May 20, 2013 2:50 pm

Re: Hypertherm powermax 85 fine cut problems

Post by COLT »

Nope messed up again I'm lost
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: Hypertherm powermax 85 fine cut problems

Post by jimcolt »

Which consumables?

Jim

COLT wrote:All consumables are brand new and when it tries to start the arc it goes down touches metal air comes on but no arc then fault code 0-30 stuck consumable. Any help please.
Mountain Home
2.5 Star Elite Contributing Member
2.5 Star Elite Contributing Member
Posts: 240
Joined: Tue Nov 17, 2009 10:39 pm
Location: AR, USA

Re: Hypertherm powermax 85 fine cut problems

Post by Mountain Home »

I have had that problem a number of times and it always turns out to be a problem with my air supply.
COLT
1 Star Member
1 Star Member
Posts: 14
Joined: Mon May 20, 2013 2:50 pm

Re: Hypertherm powermax 85 fine cut problems

Post by COLT »

I have replaced all of them swirl ring ,electrodes, shields, all tips same result. I have a descant dryer before the cutter it's not the best but broke right now and can't use this to make any money being its broke. Hypertherm said it might be a broke wire. Will test that tomorrow. Thanks for all the help
Post Reply

Return to “0-30 Fault Code”