Hypertherm powermax 45 question

Cut quality issues can be discussed here, most common issues have been discussed here and should help you.
Post Reply
rustyhook
2 Star Member
2 Star Member
Posts: 59
Joined: Sun May 20, 2012 3:19 pm

Hypertherm powermax 45 question

Post by rustyhook »

I'm getting bad cuts after only 500 inches of cutting. Thought i'd ask for suggestions for A newbie.

Hypertherm powermax 45 plasma cutter set at 45 amps
Air sorce is sufficent to plasma and plasma machine regulator indicator is adjusted correct
Material = 11 ga cold rolled CS (.125")
cut speed = 180 IPM
torch height during cutting is 1/16" off material

the pictures or of the Nozzle #220671 inside and outside.

RH
Attachments
INSIDE OF NOZZLE
INSIDE OF NOZZLE
OUTSIDE OF NOZZLE
OUTSIDE OF NOZZLE
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: Hypertherm powermax 45 question

Post by jimcolt »

It clearly is caused by an occasional pierce too close to the plate. Pierce height should be .15" (using the 220673 shield) and cut height should be .062". You need to stay at pierce height (no x, y or z motion) for the pierce delay time of .4 seconds. Piercing too close, moving before the pierce is complete allows material to blow back between the shield and the nozzle...this double arcs the nozzle causing the notching you can see on the outside of the nozzle bore....and you can also see material inside the nozzle.


Jim Colt Hypertherm
Post Reply

Return to “Plasma Cut Quality Forum”