Hi, not my field of work plasmacutting or metal working but im connecting a hypertherm 1850 to an AVC1850 and if i have understood correctly; start is easy, 3 and 4 on the 1850 to J2, 5 and 6 on the AVC168.

But the thing im unsure about, on the 1850, J15 and J16 goes to J1 on the voltage divider board on the AVC168 for height control?

And then from the 1850, where do i put the XFER signal?
weldguy
4.5 Star Elite Contributing Member
4.5 Star Elite Contributing Member
Posts: 2187
Joined: Fri Apr 17, 2009 11:48 am

Re: Starfire / Ontime AVC168

Post by weldguy »

Are you able to attach the 1850 manual showing J15, J16, etc. In addition the manual for your THC would be great.

Some equipment does not use the XFER signal, would like to see these manuals if you could.
RobertN93
1/2 Star Member
1/2 Star Member
Posts: 2
Joined: Mon Jun 10, 2024 10:36 pm

Re: Starfire / Ontime AVC168

Post by RobertN93 »

Here is the manual for the Hypertherm 1250 and the manual for CNC, AVC168

powermax1250 manual.pdf
(6.35 MiB) Downloaded 12 times
powermax1250 manual.pdf
(6.35 MiB) Downloaded 12 times
weldguy
4.5 Star Elite Contributing Member
4.5 Star Elite Contributing Member
Posts: 2187
Joined: Fri Apr 17, 2009 11:48 am

Re: Starfire / Ontime AVC168

Post by weldguy »

It looks to me as though J15 and J16 will be connected to J4 on the separate Arc Voltage divider board as the arc voltage RAW input. It is divided down to a lower voltage and comes out J1 on the same board which will be connected to the main controllers divided voltage input at J2 terminal 1 and 2.