We have had our Hypertherm Powermax 65 since we started cutting steel almost 9 years ago. It has worked nearly flawlessly in all that time, even though it has been pushed pretty hard from time to time. It came to a dead stop recently. Showing a 0-22 error which I could find very little information on, rather than turn on the gas. Luckily the fine people at Hypertherm quickly and easily diagnosed the problem, provided a work around and gave me the part number I needed to order. It was a simple air pressure switch gone bad. The switch is now replaced along with a new air filter. Just want to give accolades to the folks at Hypertherm for their help and direction. Salute!
0-22 Error on Powermax 65
- ColoradoWayne
- 2.5 Star Member
- Posts: 249
- Joined: Fri Dec 06, 2013 4:48 pm
- Location: Colorado Springs, CO
0-22 Error on Powermax 65
You currently do not have access to download this file.
To gain download access for DXF, SVG & other files Click Here
Wayne
LDR Motion Systems 4 x 4 water table
Hypertherm Powermax 65
LDR Motion Systems 4 x 4 water table
Hypertherm Powermax 65
- acourtjester
- 6 Star Elite Contributing Member
- Posts: 8183
- Joined: Sat Jun 02, 2012 6:04 pm
- Location: Pensacola, Fla
Re: 0-22 Error on PMX 65
Good feedback thanks.
DIY 4X4 Plasma/Router Table
Hypertherm PM65 Machine Torch
Drag Knife and Scribe
Miller Mig welder
13" metal lathe
Small Mill
Everlast PowerTig 255 EXT
Hypertherm PM65 Machine Torch
Drag Knife and Scribe
Miller Mig welder
13" metal lathe
Small Mill
Everlast PowerTig 255 EXT
-
- 4.5 Star Elite Contributing Member
- Posts: 2187
- Joined: Fri Apr 17, 2009 11:48 am
Re: 0-22 Error on PMX 65
That's great, thanks for the info
-
- 1/2 Star Member
- Posts: 1
- Joined: Fri Jul 28, 2023 9:02 am
Re: 0-22 Error on Powermax 65
Hi Wayne
I have the same problem now . Can I just bridge the pressure switch for a quik fix until I get a new switch.