3/8" plate question - 60 or 80 amps?

Cut quality issues can be discussed here, most common issues have been discussed here and should help you.
Post Reply
TLJC
1 Star Member
1 Star Member
Posts: 16
Joined: Wed Mar 09, 2011 9:54 am
Location: Regina, Saskatchewan, Canada
Contact:

3/8" plate question - 60 or 80 amps?

Post by TLJC »

Hello All,
I have to cut 100 pieces from 3/8" plate roughly 1" wide and 20" long with a slight bend in it. They are for a scissor like assembly we have made for years. I don't know if I should be using the 60 or 80 amp consumables for my Hypertherm powermax 1650 G3. I would like to have as little dross as possible.
Any help would be appreciated.
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: 3/8" plate question

Post by jimcolt »

I would recommend tha 60 amp process...it will provide better cut quality as compared to the 80 amp in terms of edge squareness and part accuracy.

Shield: 120930
Retaining Cap: 120928 (220061 if using ohmic contact)
Nozzle: 120931
Electrode:120926
Swirl Ring: 120925

Amperage:60
Pierce Height: .180"
Pierce delay time: .75 seconds
Cut Height: .060"
Optimum cut speed: 41 inches per minute



Jim Colt Hypertherm
TLJC
1 Star Member
1 Star Member
Posts: 16
Joined: Wed Mar 09, 2011 9:54 am
Location: Regina, Saskatchewan, Canada
Contact:

Re: 3/8" plate question

Post by TLJC »

Thanks Jim,
I cut the arms with great success!!
The quality was great with only a small angle on each side. I compared them to a previous piece cut by laser. It was vey difficult to tell the difference. The only thing I have to work on is lessening the dross. Any suggestions?
Post Reply