I cut a lot of detailed 3/16 CR plate. On the hypertherm website it says it will cut up to 3/16 with fine cut consumables.. has anyone done this? From what I've read on here it seems like I would have to set my torch height a lot higher. I'm also cutting 14ga tonight, so I will be experimenting on both! If anyone disagrees with cutting 3/16 with fine cut please let me know :geek: ! This is on a 45xp machine torch.
motoguy
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 1184
Joined: Tue Aug 25, 2015 12:05 pm
Location: Central MO, USA

Re: 3/16 vs fine cut

Post by motoguy »

I've never seen Jim Colt recommend fine cuts over 10ga (1/8"). I have seen other people cut thicker on occasion. It's probably not that it can't be done, as much as there's a significant tradeoff in consumable lifespan, or something like that.
Bulltear 6x12 w/ Proton Z axis & watertable
CommandCNC/Linux w/ Ohmic & HyT options
Hypertherm Powermax 85 w/ machine torch
Solidworks, Coreldraw X7, Inkscape, Sheetcam
Pat4rd
2 Star Member
2 Star Member
Posts: 82
Joined: Thu Apr 06, 2017 6:32 pm

Re: 3/16 vs fine cut

Post by Pat4rd »

That's what I was thinking.. I really don't think it will work as good but maybe he will chime in with a response.
Millermatic 252
Hypertherm 45xp machine torch
Eagle 4x4
Mach3, sheetcam, adobe il, inkscape
Proma 150 floating head, Quincy 5hp 60gal, 3 stage dryer.
User avatar
rdj357
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 1186
Joined: Sun Mar 11, 2012 4:40 pm
Location: Tahlequah, OK

Re: 3/16 vs fine cut

Post by rdj357 »

I have only tried 3/16 once with FC and I was not happy with the cut so I switched to regular consumables. Maybe the 45XP would do a better job than my PM65 set at 45 amps?
Robert Johnson
PlasmaCAM GURU & Instructor
I am not affiliated with PlasmaCAM, Inc. in any way. I offer training on their equipment and software. All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them are for nominative purposes only and does not imply any affiliation with or endorsement by them.
User avatar
see&see
2.5 Star Member
2.5 Star Member
Posts: 218
Joined: Tue Jun 24, 2014 12:04 pm
Location: Minden, Nevada
Contact:

Re: 3/16 vs fine cut

Post by see&see »

I tried it both ways on 3/16" .188 HR & CR , ended up going back to the 45 amp process, bit faster and less (almost zero) dross. Although I'm using AHC so the height stays right at specs.
You marry into the PlasmaCam family and must accept the fact your software and hardware are proprietary. It's a for better or for worse engagement with overwhelming security. PlasmaCam controls the computer, table, hardware to their advantage IMO. :x
Pat4rd
2 Star Member
2 Star Member
Posts: 82
Joined: Thu Apr 06, 2017 6:32 pm

Re: 3/16 vs fine cut

Post by Pat4rd »

Good to know guys, thanks for the input. I will just stick with the regular tips. im happy with my results in most cases!
Millermatic 252
Hypertherm 45xp machine torch
Eagle 4x4
Mach3, sheetcam, adobe il, inkscape
Proma 150 floating head, Quincy 5hp 60gal, 3 stage dryer.
Pat4rd
2 Star Member
2 Star Member
Posts: 82
Joined: Thu Apr 06, 2017 6:32 pm

Re: 3/16 vs fine cut

Post by Pat4rd »

Good to know guys, thanks for the input. I will just stick with the regular tips. im happy with my results in most cases!
Millermatic 252
Hypertherm 45xp machine torch
Eagle 4x4
Mach3, sheetcam, adobe il, inkscape
Proma 150 floating head, Quincy 5hp 60gal, 3 stage dryer.
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: 3/16 vs fine cut

Post by jimcolt »

The Hypertherm website does not (to the best of my knowledge) say that the Powermax45 Xp can cut 3/16" with Finecut consumables. The Finecuts are recommended for a maximum of 10 gauge...or roughly 1/8" maximum thickness. You can cut thicker, however there are no specs for cut speed, pierce height, pierce delay etc., and you should expect shorter consumable life (as compared to 10 gauge and thinner.

The 45 amp shielded consumables do an excellent job on 3/16", I see no reason to use the Finecuts....except you may get a .006" narrower kerf.

If you can point out where on the website you saw the Finecuts mentioned for thicker than 3/16" (with a 45 XP), please point it out and I will get it corrected! Best regards, Jim Colt
Pat4rd
2 Star Member
2 Star Member
Posts: 82
Joined: Thu Apr 06, 2017 6:32 pm

Re: 3/16 vs fine cut

Post by Pat4rd »

Jimcolt thanks for the info, I'm really happy with how it's cutting 3/16 with the shielded consumables :) . I'm not sure if I'm at the right place on the hypertherm website but this is where I read about the "3/16 and lower" ..thanks for clearing that up I'll try to attach a link https://www.hypertherm.com/en-US/learn/ ... e-cutting/
Attachments
IMG_3044.PNG
Millermatic 252
Hypertherm 45xp machine torch
Eagle 4x4
Mach3, sheetcam, adobe il, inkscape
Proma 150 floating head, Quincy 5hp 60gal, 3 stage dryer.
User avatar
SeanP
4 Star Member
4 Star Member
Posts: 951
Joined: Thu Aug 01, 2013 11:50 am
Location: Co Kerry, Ireland

Re: 3/16 vs fine cut

Post by SeanP »

Cut a job today with finecuts on the 45XP out of 5mm, very happy with how they cut.

Holes were marked and drilled.
FC1.jpg
FC2.jpg
settings1.jpg
settings1.jpg (30.04 KiB) Viewed 1942 times
settings1.jpg
settings1.jpg (30.04 KiB) Viewed 1942 times
Powermax XP45
Home built table, Candcnc DTHC 2, Dragoncut 620-4
R-Tech 210 Tig, Jasic 250 mig
Sheetcam, Scanything, Coreldraw
Table build gallery
urbnsr
3 Star Member
3 Star Member
Posts: 329
Joined: Wed Dec 26, 2012 6:13 am

Re: 3/16 vs fine cut

Post by urbnsr »

Very nice Sean. I have to try that. Is your pierce height setting normal or a 5mm-only setting?
User avatar
SeanP
4 Star Member
4 Star Member
Posts: 951
Joined: Thu Aug 01, 2013 11:50 am
Location: Co Kerry, Ireland

Re: 3/16 vs fine cut

Post by SeanP »

Normal for now, just went off 4mm settings and slowed down, pierced no problem, I'll no doubt try 6mm at some stage for intricate parts ;)
Powermax XP45
Home built table, Candcnc DTHC 2, Dragoncut 620-4
R-Tech 210 Tig, Jasic 250 mig
Sheetcam, Scanything, Coreldraw
Table build gallery
Brand X
3.5 Star Member
3.5 Star Member
Posts: 511
Joined: Wed Apr 23, 2014 2:48 pm

Re: 3/16 vs fine cut

Post by Brand X »

Sean,
good job!! Probably more dross then standard 45 amp shielded cutting.. There are areas where you can improve cuts by thinking out of the box..You might give up in one area, and gain in another. Like sometimes using less amps then what Hypertherm has recommended.. That goes for Esab, and Thermal Dynamics too..

I see you went with the new machine over a standard 45, and XP torch.. I think the 45XP is one of the finest power supplies built.. I like it way better overall then my 65 I had. Excellent on Power input too..

Keep up the good work, and thanks for posting the Parameters (Even if it's in Metric) :D
Pat4rd
2 Star Member
2 Star Member
Posts: 82
Joined: Thu Apr 06, 2017 6:32 pm

Re: 3/16 vs fine cut

Post by Pat4rd »

Nice!!! I normally cut 5mm I'm going to test it out this weekend.
Millermatic 252
Hypertherm 45xp machine torch
Eagle 4x4
Mach3, sheetcam, adobe il, inkscape
Proma 150 floating head, Quincy 5hp 60gal, 3 stage dryer.