Good Morning,
I have an HP 600 that has a sticking air valve. If I tap it a little it will eventually open up. Is there a way to fix this and to prevent it from happening again? I use a prefilter and two moiture filters before the cutter.
Thanks for the help, Tim Red Robin Creatives
Sticking Air Valve Hypertherm 600
-
- 2.5 Star Member
- Posts: 225
- Joined: Sun Sep 27, 2009 9:48 pm
- Dennis
- 3 Star Member
- Posts: 326
- Joined: Wed Feb 17, 2010 12:41 am
- Location: BC , Canada
Re: Sticking Valve
I use to have a hypertherm 1000.. If we are talking about the same valve you will have to replace it..I had the same problem, was not the cutters fault it was all gummed up from poor quality air.
-
- 5 Star Elite Contributing Member
- Posts: 3087
- Joined: Mon Jul 20, 2009 11:18 pm
- Location: North Carolina
Re: Sticking Valve
Some of the solenoids used on Hypertherm plasma systems can be disassembled carefully. I would attempt to take it apart and carefully clean internal components with a safe solvent...maybe rubbing alcohol, and re assemble. Keep in mind that if this does not work, you will have to replace the solenoid valve! I suggest talking with the great guys at Hypertherm tech service.....they talk people through similar fixes many times a day, they may have some tricks that can help you out! Here is the contact info:
Technical Service
technical.service@hypertherm.com
800-643-9878 Tel - Toll Free in USA
and Canada
Jim Colt Hypertherm
Technical Service
technical.service@hypertherm.com
800-643-9878 Tel - Toll Free in USA
and Canada
Jim Colt Hypertherm
-
- 2.5 Star Member
- Posts: 225
- Joined: Sun Sep 27, 2009 9:48 pm
Re: Sticking Valve
Dennis and Jim(Plasma God),
Thank you for your help. I will be taking care of this tomorrow.
My Sincere Thanks, Tim Red Robin Creatives
Thank you for your help. I will be taking care of this tomorrow.
My Sincere Thanks, Tim Red Robin Creatives
- Dennis
- 3 Star Member
- Posts: 326
- Joined: Wed Feb 17, 2010 12:41 am
- Location: BC , Canada
Re: Sticking Valve
I tried cleaning mine once it never worked right since, but it bought me sometime till the new one arrived.jimcolt wrote:Some of the solenoids used on Hypertherm plasma systems can be disassembled carefully. I would attempt to take it apart and carefully clean internal components with a safe solvent...maybe rubbing alcohol, and re assemble. Keep in mind that if this does not work, you will have to replace the solenoid valve! I suggest talking with the great guys at Hypertherm tech service.....they talk people through similar fixes many times a day, they may have some tricks that can help you out! Here is the contact info:
Technical Service
technical.service@hypertherm.com
800-643-9878 Tel - Toll Free in USA
and Canada
Jim Colt Hypertherm
-
- 2.5 Star Member
- Posts: 225
- Joined: Sun Sep 27, 2009 9:48 pm
Re: Sticking Valve
Dennis,
I guess it is time to invest in better filters. Thanks for your help.
Tim
I guess it is time to invest in better filters. Thanks for your help.
Tim
- Metal Lee
- 2.5 Star Elite Contributing Member
- Posts: 185
- Joined: Sun Oct 05, 2008 3:10 pm
Re: Sticking Air Valve Hypertherm 600
What is the cost of these valves? Is it worth having an extra one on hand? I have a 600 as well, I don't need the down time.