Trying to test fire plasma cutter on new arclight table. Everything appears to be hooked up. Only thing I see is red" hold motion" button lights up on computer screen when I hit fire button. No error message on plasma cutter. Thanks in Advance!
sphurley
3 Star Member
3 Star Member
Posts: 445
Joined: Sat Jul 04, 2015 10:43 pm

Re: Hypertherm Powermax 65 test fire

Post by sphurley »

Do you hear the relay in the PWM module "click" when you try and test fire? Are you using a machine torch or a hand torch?
Steve
Platform CNC Plasma table
CandCNC Ethercut IV DTHC
Hypertherm 85/CPC/RS485
Miller 350P
Miller Dynasty 280DX
drossmaker
2.5 Star Member
2.5 Star Member
Posts: 101
Joined: Tue Oct 12, 2010 2:36 am
Location: Bend, Oregon
Contact:

Re: Hypertherm Powermax 65 test fire

Post by drossmaker »

nostalgic design,

sphurley has some of the right things to look for. Thanks for giving us a call and getting this resolved. It always easier to 'look' at the machines over the phone or by remote access. The end result of this was no air pressure to the plasma. Glad your up and running Nostalgic Design!!